Flanged Solid Shaft Water-Cooled Ferrofluid Seal

SVF-S Series

SVF-S Series

The ferrofluid adopts insert-type connection. Two O-rings on the outer diameter of the housing connect with the chamber bore to maintain static sealing. The ferrofluid shaft sleeve is rotatable. When the drive shaft is inserted into the shaft sleeve, two O-rings inside the sleeve compress the drive shaft to form a static seal between them. The rotation of the drive shaft drives the shaft sleeve to rotate together, solving the vacuum sealing problem of the drive shaft. It is suitable for vacuum sealing at low, medium and high rotational speeds under ambient temperature.

 

详情页图片01


Solid shaft ferrofluid seal, bearing configuration: standard (supported at both ends). Water cooling: water cooling available upon request. Round straight type, flat cut keyway

The most standard flange mounting type. Bearing design with bearings fitted at both ends.

Keyway machining on the shaft is an optional specification.

图片2


  • Precautions
    (*1): Solvents (acetone, alcohol, freon, oil, water, etc.) must not enter the ferrofluid sealing device.
    (*2): Leak test shall be performed using a helium mass spectrometer leak detector.
    (*3): Pressure exceeding the specified value shall not be applied. For vacuum applications, the applied pressure is 1kg/cm²; for pressurized applications, pressure shall only be applied up to the value specified in the technical specification.
    (*4): When evacuating the vacuum chamber while the rotary shaft of the ferrofluid seal is stationary, or rotating it after remaining stationary for a long time in vacuum, the vacuum pressure will rise. This is an inherent phenomenon of ferrofluid sealing devices and can be mitigated by measures such as pre-starting.
    (*5): For water-cooled products, use room-temperature water with a flow rate of 1–3 L/min. Ordinary tap water is acceptable (chloride ion ≤200mg/L, iron content ≤0.3mg/L). In addition, condensation must be avoided, as condensation will cause bearing rust and result in poor rotation.
    (*6): Please contact our technical sales staff when using the ferrofluid seal under the following conditions.

Product Specifications

SVF4020-SSVF4025-SSVF4030-SSVF4040-SSVF4050-S
D20+0.04
+0.02
25+0.04
+0.02
30+0.04
+0.02
40+0.04
+0.02
50+0.05
+0.02
B123.5126130.5141147.5
C109.5112116.5125131.5
G789096106132
E1Width 6W × Depth 3.5D × Length 50LgWidth 8W × Depth 4D × Length 63LgWidth 10W × Depth 5D × Length 80LgWidth 12W × Depth 5D × Length 90LgWidth 14W × Depth 5.5D × Length 110Lg
E2Width 6W × Depth 3.5D × Length 40LgWidth 8W × Depth 4D × Length 53LgWidth 10W × Depth 5D × Length 70LgWidth 12W × Depth 5D × Length 80LgWidth 14W × Depth 5.5D × Length 100Lg
F5060708080
J120145145160185
K1010101212
NPD100/4-Φ10PD160/8-Φ12
H25
Allowable Transmission Torque [kg.cm]-
Vacuum Level [Torr]10-5(10-7)

Allowable Helium Leak Rate 

[Pa.m³/sec(Torr.l/sec)]

<10-10/<10-9
Pressure Resistance [kg/cm²]1.0
Operating Temperature Range [℃]0~80
Applicable GasInert Gas